November 26, 2026
Henkel’s LOCTITE 275, a high-strength anaerobic threadlocker from the Loctite brand, turns anti-loosening from a structural design problem into a materials-and-process problem, providing permanent locking and sealing for large bolts and studs from M25 upward.
Under sustained vibration, shock and cyclic loading, screws and nuts on machinery work themselves loose — one of the oldest and most stubborn failure modes in mechanical design. LOCTITE 275, an anaerobic threadlocker from Henkel’s Loctite brand, was created to address exactly that. the product is designed for permanent locking and sealing of threaded fasteners; it cures when confined in the absence of air between close-fitting metal surfaces, prevents loosening and leakage caused by shock and vibration, and is typically specified for large bolts and screws of M25 and above
acrylic technology, dimethacrylate chemistry, green liquid in the uncured state, fluorescent under UV light; single-component and requiring no mixing, medium viscosity, anaerobic cure, secondary cure via accelerator, intended for threadlocking, at high strength[1]. The UV fluorescence is not a cosmetic detail — on the shop floor it lets quality inspectors verify quickly with a UV lamp that the adhesive was in fact applied.
One point of terminology is worth flagging: this TDS lists viscosity as “medium”, whereas Henkel’s public product literature describes LOCTITE 275 as a high-viscosity, thixotropic grade for large thread sizes, with a Brookfield viscosity of roughly 5,000 to 10,000 mPa·s at 25 °C. The two are not in conflict — the first is a relative grade within the product family, the second an absolute figure under stated test conditions. For design-in, the current TDS for the batch at hand remains the authority.
The anaerobic cure principle is the foundation of the whole product family. In 1953, chemistry professor Vernon K. Krieble at Trinity College in Hartford, Connecticut, produced the anaerobic threadlocking adhesive in the laboratory; the breakthrough was a stabilisation system that suppressed polymerisation in the bottle yet permitted rapid cure once air was excluded and metal was present[3],[5]. The material stays liquid in its container, then polymerises by a free-radical reaction inside the thread gap, hardening into an insoluble solid that fills the microscopic space between mating threads.
defines the boundaries of cure rate through four sets of test curves. First, substrate: catalytic activity differs by material, and the sheet plots breakaway torque versus time for black-oxide M10 nuts and bolts on various materials per MIL-S-46163. Second, bond-line gap: the gap depends on thread type, class and size, and the sheet plots shear strength versus time on steel shafts and sleeves at controlled gaps per MIL-R-46082. Third, temperature: breakaway torque curves for M10 black-oxide nuts and bolts at different temperatures under the same standard. Fourth, accelerator: where cure is slow or the gap is large, applying an accelerator to the surface increases cure rate, and the sheet shows breakaway torque over time on zinc-dichromate steel M10 nuts and bolts using accelerators 7471 and 7649
Henkel’s published literature adds fixture-time figures commonly used in engineering: roughly 15 minutes on steel, 7 minutes on brass and 180 minutes on stainless steel. The order-of-magnitude gap for stainless is the substrate-activity variable in plain sight — passive surfaces lack the active metal ions needed for catalysis and generally call for an accelerator.
or engineers the real value sits in a measurable quantity. The TDS notes that the breakaway torque of an uncoated fastener is typically 15% to 30% below the tightening torque. That gap is precisely the preload margin that vibration consumes. LOCTITE 275 forms a continuous cured layer in the thread pair, bringing breakaway torque back toward the level of the assembly torque; the property is assessed to ISO 10964 (M10 zinc-phosphate steel nuts and bolts, one week of cure at 22 °C, 5 N·m tightening torque)
Public technical data put breakaway torque at about 25 N·m and prevailing torque at about 36 N·m on M10 steel fasteners, with a service temperature range of roughly −55 °C to +150 °C. As a high-strength, permanent-grade product, it is not intended for joints that must be broken frequently
he cured physical properties are listed as well: coefficient of thermal expansion 100 × 10⁻⁶ (ISO 11359-2), thermal conductivity 0.3 W/(m·K) (ISO 8302), specific heat 0.1 kJ/(kg·K).
On environmental resistance the TDS gives a workable table of initial-strength retention, measured at 22 °C after ageing under stated conditions:
| Environment | Temp | 100 h | 500 h | 1000 h |
|---|---|---|---|---|
| Machine oil | 125 ℃ | 85% | 85% | 75% |
| Gasoline | 22 ℃ | 100% | 100% | 100% |
| Brake fluid | 22 ℃ | 100% | 100% | 100% |
| Ethanol | 22 ℃ | 95% | 95% | 95% |
| 丙酮 / Acetone | 22 ℃ | 95% | 95% | 95% |
| 1,1,1-三氯乙烷 / 1,1,1-trichloroethane | 22 ℃ | 100% | 95% | 95% |
| 水/乙二醇 50/50 / Water-glycol 50/50 | 87 ℃ | 100% | 85% | 85% |
The machine-oil row deserves attention: after 1,000 hours at 125 °C, retention is 75%. These numbers remind designers to size long-term load margins in hot oil-bath duty on the degraded figure, not the as-cured value.
Thread loosening is hardly a new engineering problem, but neither is it solved. Research attributes basic loosening to loaded contact faces combined with clearance in the thread engagement that permits relative slip; transverse vibration makes the thread flanks slide, breaking the self-locking state, and the bearing face under the bolt head is less stable than the nut’s, so the bolt loosens more readily than the nut. In rail transit, published technical material reports that fastener loosening accounts for more than 30% of mechanical faults, and notes that roughly 90% of tightening torque is consumed by friction with only about 10% converted into axial preload — which is why friction-factor control is decisive for preload retention (that statistic carries a source date of October 2025)
Conventional counter-measures each have a physical ceiling. Spring washers, double nuts and self-locking nuts rely on added friction; split pins and safety wiring rely on mechanical constraint; wedge lock washers rely on structural jamming. Such schemes degrade under sustained vibration and carry costs in assembly labour, replacement parts after re-work, and a wider fastener inventory. Anaerobic threadlockers do not compete with these approaches so much as complement them: they fill the thread gap, turn the thread pair into a continuously loaded body, suppress micro-movement fretting between metal faces, and add a sealing function. Loctite’s own published technical communications summarise the advantages as clean and easy application, resistance to vibration and shock, suitability for many metals with more uniform assembly torque, avoidance of fretting corrosion, and a reduction in stock variety
The family behind LOCTITE 275 has a concrete historical anchor. In 1953 Vernon Krieble produced a sample that would cure in ordinary nuts and bolts from his laboratory at Trinity College; the starting point was an anaerobic material his son Robert Krieble had encountered at General Electric. The Krieble family then incorporated American Sealants; the brand name “LOCTITE” fuses LOCK and TIGHT; and on 26 July 1956 the sealant was unveiled at a press conference at the University Club of New York, marketed precisely as the answer to the fastener-loosening problem that had plagued industry. The company was renamed Loctite Corporation in 1963 and became part of Germany’s Henkel group in 1997[