LOCTITER 275 is a high-strength, high-viscosity, thixotropic, methacrylate-based anaerobic threadlocker. It is specifically designed for the permanent locking and sealing of large threaded fasteners (M25 and larger). Curing in the absence of air between close-fitting metal surfaces, it forms a hard thermoset plastic that provides robust resistance to vibration, shock, and thermal cycling.
2. Key Features & Benefits
- High-Strength Permanent Locking: Prevents loosening under severe vibration and shock; ideal for heavy-duty and permanent assemblies.
- High Viscosity & Thixotropic: Stays exactly where applied without migrating or dripping, making it perfect for vertical or overhead applications.
- One-Component Formula: No mixing is required, ensuring fast, clean, and easy application.
- UV Fluorescent: Easily visible under UV light for quick and reliable quality inspection.
- Wide Temperature Resistance: Performs reliably in service temperatures ranging from -55°C to +150°C.
- Oil Tolerant: Can cure through light coatings of industrial oils and cutting fluids without the need for extensive prior cleaning.
- Accelerator Compatible: Cure speed can be significantly increased using LOCTITER 7471 or 7649 accelerators, especially on inactive substrates or at low temperatures.
3. Technical Specifications
Uncured Properties
| Property |
Specification |
| Chemistry |
Methacrylate Ester |
| Appearance |
Green Liquid |
| Viscosity (Brookfield RVT, 25°C) |
5,000 – 10,000 mPa·s (cP) |
| Specific Gravity @ 25°C |
~1.1 |
| Fluorescence |
Yes (Visible under UV light) |
| Flash Point |
> 100°C (Refer to SDS for details) |
| Storage Conditions |
8°C to 21°C in a dry environment |
Cured Performance (Cured for 24 hours @ 22°C)
| Property |
Test Method / Substrate |
Specification |
| Breakaway Torque |
MIL-S-46163 |
20 – 50 N·m |
| Avg. Removal Torque |
MIL-S-46163 |
25 – 50 N·m |
| Max. Avg. Removal Torque |
DIN 54454 |
35 – 65 N·m |
| 1-Hour Breakaway Torque |
MIL-S-46163 |
15 – 36 N·m |
| Compression Shear Strength |
MIL-R-46082 |
≥ 11 N/mm² (psi) |
| Service Temperature Range |
- |
-55°C to +150°C |
4. Typical Applications & Limitations
Applications:
- Locking and sealing large bolts and studs (M25 and above).
- Heavy transportation equipment, engine assemblies, and heavy machinery.
- Industrial pumps, compressors, and gearboxes.
- Structural fasteners requiring permanent, vibration-proof locking.
Limitations:
- Not recommended for use in pure oxygen systems, chlorine, or other strong oxidizing agents.
- Generally not suitable for plastics, especially thermoplastics that may be subject to stress cracking.
5. Usage Instructions
- Cleaning: Clean all surfaces (both threaded and unthreaded) thoroughly with a suitable solventand allow to dry.
- Preparation: If the surfaces are inactive (e.g., stainless steel, plated surfaces) or if rapid curing is required, apply LOCTITER 7649 or 7471 activator and let it dry.
- Application: Apply the adhesive directly to the threaded area. For through-holes, apply to the area where the nut will sit. For blind holes, apply to the bottom of the hole and the threads. Skip the first one or two threads to prevent contamination.
- Assembly: Assemble and tighten the fasteners to the specified torque.
- Curing: Allow the assembly to cure. Full strength is typically achieved in 24 hours at room temperature.
- Disassembly: As a high-strength permanent threadlocker, standard hand tools are usually insufficient. Heat the nut/bolt assembly locally to approximately 250°C and remove while hot using hand tools.
- Cleaning: Remove any uncured excess adhesive with a clean cloth or solvent. For cured adhesive, soak in solvent and use mechanical abrasion (wire brushing).
6. FAQ (Frequently Asked Questions)
Q1: What size fasteners is LOCTITER 275 suitable for?A: It is specifically formulated for large threaded fasteners, typically M25 (approx. 1 inch) and larger.
Q2: Can LOCTITER 275 be disassembled?A: It is designed for permanent locking. Disassembly is very difficult at room temperature. You will need to heat the assembly to approximately 250°C to break the bond, and remove the parts while they are hot.
Q3: How long does it take to cure?A: Fixture time on steel is typically around 15 minutes. However, it requires 24 hours at room temperature to reach its full cured strength.
Q4: Can I use it on stainless steel or plated surfaces?A: Yes, but these are considered "inactive" substrates which slow down the cure time. For faster curing on these materials, it is highly recommended to use a primer/activator like LOCTITER 7649 or 7471.
Q5: Is it resistant to chemicals and temperatures?A: Yes, it withstands continuous service temperatures from -55°C to +150°C and is highly resistant to oils, fuels, brake fluids, and various industrial solvents.
Q6: How do I inspect if the adhesive has been applied?A: LOCTITER 275 fluoresces under UV (black) light, making it very easy for quality control inspections to verify application.